I have an HP ProLiant ML 350 G5 with E200i Controler running Windows Server 2008 R2 x64
It have four disks drives models DG072A9BB7 firmware HPD0, with two logical drives C: and D: booth with raid 1-0 runing for months
I add four new disks models DG0072BALVL firmware HPD4, and I add two logical drives E: and F: booth with raid 1-0
Everything work fine, the WS 2008 R2 recognize the drives C:, D:, E: and F:
But I upgrade the drivers and firmware with SMART START 8.3 for WS 2008 R2 x64
After reboot the server, the new four hard disks models DG0072BALVL turn on amber light and the drives E: and F: dont appear, the drives C: and D: models DG072A9BB7 still work fine
Pressing F8 boot time controler utility, all four new drives models DG0072BALVL dont appear, only appear the old ones
With HP Array Configuration Utility (ACU), all four new drives models DG0072BALVL dont appear, only appear the old ones
It is hard disk firmware failure ?