Jul
15
comment Do I need to RAID Fusion-io cards?
The PCIe bus will keep up. The software RAID (if I NEED to) will be ZFS-based, so it's capable. I've ordered two cards for now, but Fusion-io literature seems to say, "one card is good enough".
Jul
15
asked Do I need to RAID Fusion-io cards?
Jul
15
revised RAID of SATA SSDs or PCIe Flash?
deleted 2 characters in body
Jul
14
comment 2 x Dual Core vs 1 x Quad Core Performance
@Recursieve Right, this is what the manufacturers intend for people to use. There are also ways to do this at the OS level. Check with your application vendor to see if this is acceptable. And please mark an answer!
Jul
14
answered VMware esxi and windows server 2008 R2 DC
Jul
13
comment DL385 G2 powering off after some time
K. Then it's the LED panel or the system board. Just get another unit so you don't waste the time.
Jul
13
revised DL385 G2 powering off after some time
added 88 characters in body
Jul
13
comment DL385 G2 powering off after some time
The ILO2 log would be key here. Remember, the ILO stays alive even when the server is powered off. Check the time/date and see if the ILO2 reports something like, "Server power removed" in the logs.
Jul
13
comment DL385 G2 powering off after some time
@PeterDian You could get another system board, but it's far easier to buy another of the same unit if you intend to keep this server for some time. They're inexpensive.
Jul
13
revised DL385 G2 powering off after some time
deleted 5 characters in body; edited tags
Jul
13
revised DL385 G2 powering off after some time
added 88 characters in body
Jul
13
comment DL385 G2 powering off after some time
The DL385 G2 was introduced in 2006. THey didn't really make it out into the field until 2007. From a technology perspective, it's similar to the first-runs of the G5 Intel ProLiants. So it has P400-era Smart Array controllers and SAS/SATA drives.
Jul
13
answered DL385 G2 powering off after some time
Jul
13
awarded  Nice Answer
Jul
13
comment Restarting a program with monit
Please show your Monit configuration.
Jul
13
comment How do I inform my ESXi 5 host(s) of a power outage?
Revisiting this. In 2013, how should this be done?
Jul
13
revised How do I inform my ESXi 5 host(s) of a power outage?
edited tags
Jul
13
reviewed Approve Hosting a ZFS server as a virtual guest
Jul
12
revised Best practices for power cabling racks in DC
added 85 characters in body
Jul
12
revised Enabling VMware EVC on Westmere E5645 CPU only accepts “Nehalem” mode
added 176 characters in body