2

I am running a RAID 1+0 on a HP ProLiant DL360 G5 with 6 disks (each 146 GB).

The mirror groups looks as follows:

Group 1

  • 146 GB 1-Port SAS Drive at Port 1l: Box1:Bay1
  • 146 GB 1-Port SAS Drive at Port 1l: Box1:Bay2
  • 0 GB 1-Port SAS Drive at Port 1l: Box1:Bay3

Group 2

  • 146 GB 1-Port SAS Drive at Port 1l: Box1:Bay4
  • 146 GB 1-Port SAS Drive at Port 2l: Box1:Bay5
  • 0 GB 1-Port SAS Drive at Port 2l: Box1:Bay6

Unfortunately the disks in bay 3 and bay 6 are not working anymore (almost since the same time). Is there a chance to get the system back online again by replacing disk 3 + 6 by new ones?

* UPDATE *

It's a MS Server 2003 R2. I've got the information that the disks are broken from the HP smart start CD diagnostics tool. The following versions are in place: * ACU Version 8.60.7.0 * Diagnostic Module Version 5.2.52.0 * INFOMGR Version 5.9-29.0

Server was already off (pressing power button) when people involved me. ROM/RAM firmware revision is 2.10

7
  • Is this a Linux system or Windows system? Where is this output coming from? hpacucli?
    – ewwhite
    Feb 25, 2013 at 15:48
  • 1
    Also, when did the drives fail?
    – ewwhite
    Feb 25, 2013 at 15:58
  • Thanks for the answers so far. Will check system / firmware details tomorrow. Is then the mirroring between Group 1 and Group 2 and the striping within the group itself?
    – user161767
    Feb 25, 2013 at 20:47
  • @YvesSturzenegger the mirrored pairs are striped...
    – ewwhite
    Feb 25, 2013 at 20:52
  • @YvesSturzenegger We need the controller and server firmware revisions. Did you try the powering-down as I suggested? Are there any filesystem errors on the server?
    – ewwhite
    Feb 26, 2013 at 8:41

2 Answers 2

1

If you can shut the system down gracefully, you can be able to jog the disks through a simple power-down operation.

You're correct in that the mirror groups mate RAID1 pairs from each group, as in this example.

If you can get the system off and the drives spun down (also remove power), there's some hope that they'll spin up and give the controller a chance to perform an array recovery.

Of course, at the same time, you'll want to get spares or replacements ready or on the way.

Can you share the specific server model, firmware, OS and other details? There are cases of early firmware revisions of that Smart Array P400 giving false-positive failure indications on drives, so a comprehensive evaluation of your firmware and system health is in order.


Edit:

You say the Smart Array P400 RAID controller's firmware version is 2.10 from May 2007. The current version of firmware for that system is 7.18!!

You are severely behind. Also, I suggested pulling the power cables to the system for a few minutes and trying a cold start. Take close note of the RAID controller messages as the system boots. Or does the system even boot properly? Do the physical disks have error lights illuminated?

Can you try a firmware update of all of the components using the bootable HP Firmware DVD just to rule-out bad firmware interactions or a false-positive disk failure?

2
  • I just updated the firmware (7.22). Unfortunately, it's still not working. Looks like the disks are broken. RAID controller error message is: "disk drives are failed and should be replaced". Error lights are red for the two disks. System boots up to the point where it says "Non-system disk or disk error".
    – Yves
    Feb 27, 2013 at 9:37
  • Oh well... I doubt that the drives failed at the same time, so going forward, you will need to add the HP monitoring agents so that you can obtain email or SNMP alerts to drive failures... or at the very least, give the system a quick visual check to look for red lights. They RAID controller may have given you an F1 option to attempt data recovery during post. Reboot and try that. If it doesn't, your data is gone.
    – ewwhite
    Feb 27, 2013 at 9:48
0

If disk 3 and 6 have failed and they won't come back online, then no, you can not get your data back.

1
  • Not necessarily... It depends upon what's being shown at the OS level. This is an old system, and people tend not to keep firmware updated. There were early firmware revisions of that controller that falsely marked drives as failed...
    – ewwhite
    Feb 25, 2013 at 15:57

You must log in to answer this question.

Not the answer you're looking for? Browse other questions tagged .