i changed my HP 410 smart array controller from one pci slot to another because it was faulty. After the change the logical unit i had fails showing one disk as unassigned and a new one into the array
Smart Array P410 in Slot 5 (sn: PACCRID11231CTT)
array A (SATA, Unused Space: 0 MB)
logicaldrive 1 (931.5 GB, RAID 1, Interim Recovery Mode)
physicaldrive 0:1 (box 0:bay 1, SATA, 0 MB, Failed)
physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SATA, 1 TB, OK)
unassigned
physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SATA, 1 TB, OK)
Is there any way to change the failed physicaldrive for the unassigned? the physicaldrive 0:1 doesn't exist.