1

I have a 3ware 8 channel SAS controller and a back plane extender (also 8 channel) which can take 16 drives. I will be creating a single RAID 10 volume.

I know that adding more drives has positive effect on performance, but I'm not sure if adding more than 8 drives on an 8 channel controller will have any positive impact at all. Am I wrong?

Should I put 16 drives for best performance? Would 8 drives give me the same performance?

2
  • What model 3ware RAID controller is it? Sep 3, 2009 at 12:55
  • It is 9690SA-8I with 512MB cache.
    – Tvrtko
    Sep 3, 2009 at 13:11

2 Answers 2

1

My basic gut reaction would be to fill the controller if you can. If I understand correctly, it mirrors on the channel and stripes across them, suggesting that 16 drives (2 per channel) would be the smart thing to do.

I may be wrong, however.

1

The SATAII spec...also called SATA 300 and SATA 3Gb just means that the bus rate is 3Gbit/s which works out to be roughly 300MB/s. Hence the other names. However a single drive doesn't saturate this bus. Not even the SSD drives can saturate it currently.

Your controller has two multi-lane 4x ports. As long as the extender also has 2 multi-lane 4x ports then you should be able to safely put 16 drives without introducing any bottle necks. At least not between the drives and the controller.

You must log in to answer this question.

Not the answer you're looking for? Browse other questions tagged .