(Not sure on the model at the moment will update once I know)
So we had a a RAID 5 that had two hard drives fail at the same time.
Positions 0 and and 1 are labeled as "online". Positions 2 and 3 are labeled as "failed".
We had a backup drive (of course) and put it in position 2. The drive is still telling us as position 2 as "failed". Is this usual behavior? Is won't let us rebuild of course since we lost two drives.
(To make sure the controller wasn't just the thing that died, we tried switching the drives around. Switched 0 and 2 positions' cords. 0 went to failed while 2 went to online. The problems followed the drives)
What should we do?
EDIT: Put in the new drive and now on boot it's saying "unresolved configuration mismatch between disk(s) and NVRAM on the adapter" No idea what that means. xD