4

Michael is correct. The HP documentation states under Interfaces): Network: RJ-45 (10/100/1000 bits/s Ethernet) (1) Remote Management: HP ProLiant Onboard Administrator (Powered by the HP Integrated Lights-Out 100i Baseboard Management Controller) The server only has a single NIC.


1

I remembered that my VM had "Dynamic Memory" enabled so I tried running the VM with "Dynamic Memory" turned off. After stress-testing the VM, all 12 physical cores lit up. Happy for anyone out there to extend this answer by explaining why this solved my issue.


1

You may disable this predictive failure drive and this will initiate rebuilding with spare drive if you have it in configuration(you have): hpacucli controller slot=6 physicaldrive 1I:1:1 modify disablepd The second variant is to change drive spare activation mode: hpacucli controller slot=6 modify spareactivationmode=predictive But it is not supported for ...


Only top voted, non community-wiki answers of a minimum length are eligible